Sleeves + Gaskets

Skip to results list

Shop

Installation sleeves and gaskets

Each LUNOS unit sits in a round sleeve that runs through the outside wall. New units already come with their sleeves. Shop here to replace a sleeve that was cut too short, damaged or lost, to get the longer sleeve for a thicker wall, or to add a gasket or a wind pressure flap.

  • Cut to your wall depth
  • Same sleeve for the e² and eGO
  • Shipped within Canada

Choose your part

The e² series and the eGO use the same round sleeve, 160 mm (6 5⁄16") across, so the sleeve and the gasket fit every unit. The wind pressure flap is for the e² series only.

Installation sleeve

e² series and eGO

Installation sleeve

The round sleeve each unit sits in.

500 mm (19.7") or 700 mm (27½")

What it is. A polypropylene tube, 160 mm (6 5⁄16") across, that lines the hole through the wall and holds the unit. It comes with two foam caps that keep plaster and dust out until the unit goes in.

Which length. The 500 mm (19.7") is the sleeve that comes with the e² Standard and with the eGO’s long sleeve option; for an e² Short, buy the 500 mm and cut it down. The 700 mm (27½") is for walls thicker than 19.7", so contact us before ordering for a wall that thick.

Installing it. Drill a 162 mm (6⅜") hole, with a hole saw in a wood-frame wall or a core drill in masonry or concrete, sloping down about 3 mm toward the outside. Cut the sleeve so it ends flush with the finished surface inside and out, then seal it all the way around, inside and outside.

KabSeal Pro gasket

e² series and eGO

KabSeal Pro gasket

An optional rubber gasket that seals around the sleeve on the outside.

One size · 150–165 mm

What it does. It seals the sleeve to the weather barrier on the outside of the wall, in place of tape. The sealant around the sleeve still goes on.

Good to know. It’s flexible EPDM rubber, so it moves with the wall as it shifts and as temperatures change. One size fits every e² series and eGO sleeve; you need one per sleeve, so two for an e² pair. It’s optional and doesn’t come with the units.

Wind pressure flap

e² series

Wind pressure flap

Limits drafts through the unit on walls exposed to strong wind.

For walls 14⅝" (370 mm) or thicker

What it does. Strong wind pushing on the outside wall can force extra air through the unit and cause drafts. The flap sits inside the sleeve and closes against strong wind to limit them. Some air still flows when it’s closed, and it doesn’t change the unit’s airflow or heat recovery.

Good to know. It needs a wall at least 14⅝" (370 mm) thick, finished surface to finished surface. The e² Standard fits walls from 10½", so check your wall before ordering. It doesn’t fit the e² Short. It’s recommended where strong winds are common.

Installing it. It can be added to a unit that’s already installed. Turn off the power first, then pull the unit out of the sleeve by its loop.

Installing a sleeve

The sleeve goes in before the unit. In new construction, leave it long enough on both sides to end flush with the finished wall surfaces, inside and out.

Seal the sleeve all the way around, inside and outside, with a suitable sealant. On the outside, the optional KabSeal Pro gasket also seals it to the weather barrier, in place of tape.

Tools: a 162 mm (6⅜") hole saw or core drill, a measuring tape, a mitre saw or hand saw, a level, and a caulking gun with a suitable sealant.

Step-by-step instructions are in the installation manuals for the e² series and the eGO, on our Downloads page.